Re: acess static attributes in post-exit of class method
solved by myself .calling by class name=>attribute name
View ArticleRe: MB1A - LSMW error Formatting error in the field MSEG-GRUND
Hello Sairam, Thank you very much & much appreciate your prompt reply. I'm not sure how "GRUND" field was missing from recording. I very well recorded it while creating the LSMW. As suggested, I...
View ArticleRe: Custom field in WPOHF4C and WPOHF4X
Hi Even i have a similar requirement to capture the dateline header details liek the transportation chain(TC_ID_EXT) from the transaction code WPOHF4X. I need to get the value entered on the screen. I...
View ArticleAdicionar coluna na aba Divis. mont. da MIRO
Ola, Estou tentando adicionar a coluna Vencimento na aba de Divisão de Montante na MIRO, saberiam dizer se tenho que usar userexit, Badi, enhancement e como posso fazer isso?
View ArticleRe: Enhancement to be done for an extractor!
I have a similar situation here, where I need to add COEP-VBUND into the extractor 0CO_OM_OPA_6. My solution is as followed: 1. In the structure ICORDCSTA1, add an append structure ZBWOM2_COBK_COEP2....
View ArticleRe: Adicionar coluna na aba Divis. mont. da MIRO
Hi, maybe: BADI_FDCB_SUBBAS04 for Header level,and for item level ibadi: MRM_ITEM_CUSTFIELDS Best regards,Pablo
View ArticleRe: MB1A - LSMW error Formatting error in the field MSEG-GRUND
Hello Sairam, I hope you got the issue that is occuring now.It's giving above shown error when i execute in background.Any idea how to fix this. Please suggest/help/guide. Thanks in advance.
View ArticleRe: want to park inbound invoice idocs instead of booking them through
Thank you for the note No
View ArticleRe: Localizing a Custom Tab in a Tabstrip Control of ME21N/ME22N at Item level
Hi Kauthub, Please let me know if you have found a suitable solution for it.I am also stuck with same issue. Thanks.Arjav
View ArticleME52/51N Enhancment
Hi All,My client requirement is to set default value of PO price of all line items when the save the PR. I am using ME_PROCESS_REQ_CUST BADI and POST interface but result is not reflecting, below are...
View ArticleRe: Adicionar coluna na aba Divis. mont. da MIRO
Pablo, thanks for your help, but didn't work...
View ArticleRe: Adicionar coluna na aba Divis. mont. da MIRO
Now, I need add a column on FDCB-LFDCBFM0 Table Control: TCSPLT.How can I do it? Here is my code, but it doesn't work: DATA: ls_cols TYPE LINE OF scxtab_column_it, ls_intcol TYPE screen,...
View ArticleRe: MB1A - LSMW error Formatting error in the field MSEG-GRUND
Dear Shaiz, I guess the screen fields are changing dynamically based on the moment type or on something else. Make sure you write some conditions under step#5 based on the field status group....
View ArticleRe: ME52/51N Enhancment
Ok. you mean set_datax should be called after set_data. I reset the position of set_datax to after set_data. and run tcode ME52N change the data, but it is not reflecting the bpueb = 1. regards
View ArticleRRX_GRID_CMD_PROCESS issue
Hi Experts, Fm RRX_GRID_CMD_PROCESS doesn not return any value in KAP system. We were using this Function Module in GRP system to read the BI query data and drilldown the query output.Our custom Fm has...
View ArticleRe: Table is Not storing all data's
Hi Praveen, Can you please help me if you can solve my problem..
View Article